<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AVR &#8211; TNK Genparts</title>
	<atom:link href="https://tnkgenparts.com/product-tag/avr/feed/" rel="self" type="application/rss+xml" />
	<link>https://tnkgenparts.com</link>
	<description>Generator spare parts</description>
	<lastBuildDate>Fri, 22 Mar 2024 12:38:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.1</generator>

<image>
	<url>https://tnkgenparts.com/wp-content/uploads/2024/02/cropped-Site-logo-32x32.png</url>
	<title>AVR &#8211; TNK Genparts</title>
	<link>https://tnkgenparts.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>R450M</title>
		<link>https://tnkgenparts.com/product/r450m/</link>
					<comments>https://tnkgenparts.com/product/r450m/#respond</comments>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:36 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=824</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li><span id="page17R_mcid132" class="markedContent"><span dir="ltr" role="presentation">The R450M AVR is supplied in a casing</span></span><span id="page17R_mcid133" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">designed to be mounted on a panel with</span></span><span id="page17R_mcid134" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">dampers.</span></span><span id="page17R_mcid135" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Operating temperature: - 40°C to + 65°C</span></span><span id="page17R_mcid136" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Storage temperature: -- 55°C to + 85°C</span></span><span id="page17R_mcid137" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Shocks on the base: 9 g depending on the</span></span><span id="page17R_mcid138" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">3 axes.</span></span><span id="page17R_mcid139" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">-</span> <span dir="ltr" role="presentation">Vibrations:</span> <span dir="ltr" role="presentation">less</span> <span dir="ltr" role="presentation">than</span> <span dir="ltr" role="presentation">10</span> <span dir="ltr" role="presentation">Hz,</span> <span dir="ltr" role="presentation">2</span> <span dir="ltr" role="presentation">mm</span></span><span id="page17R_mcid140" class="markedContent"></span><span id="page17R_mcid141" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">half-peak amplitude.</span></span><span id="page17R_mcid142" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">10 Hz to 100 Hz: 100mm/s, above 100 Hz</span></span><span id="page17R_mcid143" class="markedContent"><br role="presentation" /></span></li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/R450MT.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://tnkgenparts.com/product/r450m/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>R450T</title>
		<link>https://tnkgenparts.com/product/r450t/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:36 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=825</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li><span id="page17R_mcid132" class="markedContent"><span dir="ltr" role="presentation">The R450T AVR is supplied in a casing</span></span><span id="page17R_mcid133" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">designed to be mounted on a panel with</span></span><span id="page17R_mcid134" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">dampers.</span></span><span id="page17R_mcid135" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Operating temperature: - 40°C to + 65°C</span></span><span id="page17R_mcid136" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Storage temperature: -- 55°C to + 85°C</span></span><span id="page17R_mcid137" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Shocks on the base: 9 g depending on the</span></span><span id="page17R_mcid138" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">3 axes.</span></span><span id="page17R_mcid139" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">-</span> <span dir="ltr" role="presentation">Vibrations:</span> <span dir="ltr" role="presentation">less</span> <span dir="ltr" role="presentation">than</span> <span dir="ltr" role="presentation">10</span> <span dir="ltr" role="presentation">Hz,</span> <span dir="ltr" role="presentation">2</span> <span dir="ltr" role="presentation">mm</span></span><span id="page17R_mcid140" class="markedContent"></span><span id="page17R_mcid141" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">half-peak amplitude.</span></span><span id="page17R_mcid142" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">10 Hz to 100 Hz: 100mm/s, above 100 Hz</span></span><span id="page17R_mcid143" class="markedContent"><br role="presentation" /></span></li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/R450MT.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R438</title>
		<link>https://tnkgenparts.com/product/r438/</link>
					<comments>https://tnkgenparts.com/product/r438/#comments</comments>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:36 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=826</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li>
<div class="textLayer" data-main-rotation="0"><span class="markedContent"><span dir="ltr" role="presentation">R438 </span></span><span class="markedContent"><span dir="ltr" role="presentation">AVRs</span></span><span id="page27R_mcid165" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Storage : -55°C ; +85°C</span></span><span id="page27R_mcid166" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Operation : -40°C ; +70°C</span></span><span id="page27R_mcid167" class="markedContent"></span><span id="page27R_mcid168" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Standard power supply: AREP or PMG.</span></span><span id="page27R_mcid169" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Rated overload current: 8 A - 10 s</span></span><span id="page27R_mcid170" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">-</span> <span dir="ltr" role="presentation">Electronic</span> <span dir="ltr" role="presentation">protection</span> <span dir="ltr" role="presentation">(overload,</span> <span dir="ltr" role="presentation">short-</span></span><span id="page27R_mcid171" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">circuit on opening of voltage sensing circuit): </span></span><span id="page27R_mcid172" class="markedContent"><span dir="ltr" role="presentation">excitation overload current for 10 seconds </span></span><span id="page27R_mcid173" class="markedContent"><span dir="ltr" role="presentation">then</span> <span dir="ltr" role="presentation">return</span> <span dir="ltr" role="presentation">to</span> <span dir="ltr" role="presentation">approximately</span> <span dir="ltr" role="presentation">1A.</span> <span dir="ltr" role="presentation">The </span></span><span id="page27R_mcid174" class="markedContent"><span dir="ltr" role="presentation">alternator must be stopped (or the power </span></span><span id="page27R_mcid175" class="markedContent"><span dir="ltr" role="presentation">switched off) in order to reset the protection.</span></span><span id="page27R_mcid176" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Fuse : F1 on X1, X2. 8A ; slow - 250V</span></span><span id="page27R_mcid177" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Voltage sensing : 5 VA isolated via trans</span></span><span id="page27R_mcid178" class="markedContent"><span dir="ltr" role="presentation">former ;</span></span><span id="page27R_mcid179" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">• 0-110 V terminals =</span> <span dir="ltr" role="presentation">95 to 140 V,</span></span><span id="page27R_mcid180" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">• 0-220 V terminals = 170 to 260 V,</span></span><span id="page27R_mcid181" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">• 0-380 V terminals = 340 to 520 V.</span></span><span id="page27R_mcid182" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Voltage regulation ±</span></span><span id="page27R_mcid183" class="markedContent"> <span dir="ltr" role="presentation">0.5</span></span><span id="page27R_mcid184" class="markedContent"><span dir="ltr" role="presentation">%.</span></span><span id="page27R_mcid185" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Normal or rapid response time via</span></span><span id="page27R_mcid186" class="markedContent"> <span dir="ltr" role="presentation">ST2</span></span><span id="page27R_mcid187" class="markedContent"></span><span id="page27R_mcid188" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">jumper (see below).</span></span><span id="page27R_mcid189" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Voltage adjustment via potentiometer</span></span><span id="page27R_mcid190" class="markedContent"> <span dir="ltr" role="presentation">P2</span></span><span id="page27R_mcid191" class="markedContent"><span dir="ltr" role="presentation">.</span></span><span id="page27R_mcid192" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">other voltages via adapter transformer</span></span><span id="page27R_mcid193" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Current sensing (parallel operation): C.T.</span></span><span id="page27R_mcid194" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">2.5 VA cl1, secondary 1 A (optional).</span></span><span id="page27R_mcid195" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">-</span> <span dir="ltr" role="presentation">Quadrature</span> <span dir="ltr" role="presentation">droop</span> <span dir="ltr" role="presentation">adjustment</span> <span dir="ltr" role="presentation">via</span></span><span id="page27R_mcid196" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">potentiometer</span></span><span id="page27R_mcid197" class="markedContent"> <span dir="ltr" role="presentation">P1</span></span><span id="page27R_mcid198" class="markedContent"><span dir="ltr" role="presentation">.</span></span><span id="page27R_mcid199" class="markedContent"><br role="presentation" /></span></div>
<span id="page17R_mcid143" class="markedContent"> </span></li>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/R438.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://tnkgenparts.com/product/r438/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>MX341</title>
		<link>https://tnkgenparts.com/product/mx341/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=764</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li>MX341 is a two phase sensed Automatic Voltage
Regulator and forms part of the excitation system for a
brush-less generator. Excitation power is derived from a
three-phase permanent magnet generator (PMG), to
isolate the AVR control circuits from the effects of non-
linear loads and to reduce radio frequency interference on
the generator terminals. Sustained generator short circuit
current is another feature of the PMG system.</li>
 	<li>The AVR senses the voltage in the main generator
winding and controls the power fed to the exciter stator
and hence the main rotor to maintain the generator output
voltage within the specified limits, compensating for load,
speed, temperature and power factor of the generator.
Soft start circuitry is included to provide a smooth
controlled build up of generator output voltage.</li>
 	<li>A frequency measuring circuit continually monitors the
shaft speed of the generator and provides under-speed
protection of the excitation system by reducing the
generator output voltage proportionally with speed below
a pre-settable threshold. A further enhancement of this
feature is an adjustable volts per Hertz slope to improve
engine recovery time on turbo charged engines. Soft start
circuitry is included to provide a smooth controlled build
up of generator output voltage.</li>
 	<li>Uncontrolled excitation is limited to a safe period by
internal shutdown of the AVR output device. This
condition remains latched until the generator has
stopped.</li>
 	<li>Provision is made for the connection of a remote voltage
trimmer, allowing the user fine control of the generator's
output.</li>
 	<li>An analogue input is provided allowing connection to a
Newage Power Factor controller or other external devices
with compatible output.</li>
 	<li>The AVR has the facility for droop CT connection, to allow
parallel running with other similarly equipped generators.</li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Specifications</a></h6>
<p><strong>SENSING INPUT</strong><br role="presentation" />Voltage 190-264V ac max, 1 phase, 2 wire<br role="presentation" />Frequency 50-60 Hz nominal</p>
<p><br role="presentation" /><strong>POWER INPUT (PMG)</strong><br role="presentation" />Voltage 140-220V ac max, 3 phase, 3 wire<br role="presentation" />Current 3A/phase<br role="presentation" />Frequency 100-120 Hz nominal</p>
<p><br role="presentation" /><strong>OUTPUT</strong><br role="presentation" />Voltage max 120V dc<br role="presentation" />Current continuous 2.7 A<br role="presentation" />Intermittent 6A for 10 secs.<br role="presentation" />Resistance 15 ohms minimum</p>
<p><br role="presentation" /><strong>REGULATION</strong><br role="presentation" />+/- 1% (see note 1)</p>
<p><br role="presentation" /><strong>THERMAL DRIFT</strong><br role="presentation" />0.03% per oC change in AVR ambient (note 2)</p>
<p><br role="presentation" /><strong>SOFT START RAMP TIME</strong><br role="presentation" />3 seconds</p>
<p><br role="presentation" /><strong>TYPICAL SYSTEM RESPONSE</strong></p>
<p>AVR Response 10 ms<br role="presentation" />Filed current to 90% 80 ms<br role="presentation" />Machine Volts to 97% 300 ms</p>
<p><br role="presentation" /><strong>EXTERNAL VOLTAGE ADJUSTMENT</strong><br role="presentation" />+/-10% with 1 k ohm 1 watt trimmer (see note 3)</p>
<p><br role="presentation" /><strong>UNDER FREQUENCY PROTECTION</strong></p>
<p>Set point 95% Hz (see note 4)<br role="presentation" />Slope 170% down to 30 Hz</p>
<p><br role="presentation" /><strong>UNIT POWER DISSIPATION</strong><br role="presentation" />12 watts maximum</p>
<p><br role="presentation" /><strong>ANALOGUE </strong><strong>INPUT </strong></p>
<p>Maximum input +/- 5V dc (see note 5)<br role="presentation" />Sensitivity 1v for 5% Generator Volts (adjustable)<br role="presentation" />Input resistance 1k ohm</p>
<p><br role="presentation" /><strong>QUADRATURE DROOP INPUT</strong><br role="presentation" />10 ohms burden<br role="presentation" />Max. sensitivity: 0.07 A for 5% droop 0PF<br role="presentation" />Max. input: 0.33 A</p>
<p><br role="presentation" /><strong>OVER EXCITATION PROTECTION</strong><br role="presentation" />Set point 75 V dc<br role="presentation" />Time delay 10 seconds (fixed)</p>
<h6 id="elementor-tab-title-2182" role="tab" data-tab="2" aria-controls="elementor-tab-content-2182"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/MX341.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MX321</title>
		<link>https://tnkgenparts.com/product/mx321/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=765</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li>MX321 is a three phase sensed Automatic Voltage
Regulator and forms part of the excitation system for a
brush-less generator. Excitation power is derived from a
three-phase permanent magnet generator (PMG), to
isolate the AVR control circuits from the effects of non-
linear loads and to reduce radio frequency interference on
the generator terminals. Sustained generator short circuit
current is another feature of the PMG system.</li>
 	<li>The AVR senses the voltage in the main generator winding
and controls the excitation to maintain the generator output
voltage within the specified limits, compensating for load,
speed, temperature and power factor of the generator.
Three phase RMS sensing is employed for superior
voltage regulation.</li>
 	<li>Adjustable Soft start circuitry is included to provide a
smooth controlled build up of generator output voltage.</li>
 	<li>A frequency measuring circuit continually monitors the
shaft speed of the generator and provides under-speed
protection of the excitation system by reducing the
generator output voltage proportionally with speed below a
pre-settable threshold. A further enhancement of this
feature is an adjustable volts per Hertz slope and voltage
recovery time, to improve the response of turbo charged
engines.</li>
 	<li>Current limiting may be included to allow control over the
amount of sustained short circuit current.</li>
 	<li>Maximum excitation is limited to a safe period by internal
shutdown of the AVR output device. This condition remains
latched until the generator has stopped.</li>
 	<li>The AVR includes an over-voltage protection feature with
internal shutdown of the AVR output device, plus the ability
to trip an optional excitation circuit breaker if required.</li>
 	<li>Provision is made for the connection of a remote voltage
trimmer, allowing the user fine control of the generator's
output.</li>
 	<li>An analogue input is provided allowing connection to a
Newage Power Factor controller or other external device
with compatible output.</li>
 	<li>The AVR has the facility for droop CT connection, to allow
parallel running with other similarly equipped generators.</li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Specifications</a></h6>
<p><strong>SENSING INPUT</strong><br role="presentation" />Voltage 190-264V ac max, 2 or 3 phase<br role="presentation" />Frequency 50-60 Hz nominal</p>
<p><br role="presentation" /><strong>POWER INPUT (PMG)</strong><br role="presentation" />Voltage 170-220V ac max, 3 phase, 3 wire<br role="presentation" />Current 3A/phase<br role="presentation" />Frequency 100-120 Hz nominal</p>
<p><br role="presentation" /><strong>OUTPUT</strong><br role="presentation" />Voltage max 120V dc<br role="presentation" />Current continuous 3.7 A (see note 1)<br role="presentation" />Intermittent 6A for 10 secs.<br role="presentation" />Resistance 15 ohms minimum</p>
<p><br role="presentation" /><strong>REGULATION</strong><br role="presentation" />+/- 0.5% RMS with 4% engine governing (see note 2)</p>
<p><br role="presentation" /><strong>THERMAL DRIFT</strong><br role="presentation" />0.02% per deg. C change in AVR ambient (note 3)</p>
<p><br role="presentation" /><strong>SOFT START RAMP TIME</strong><br role="presentation" />0.4 – 4 seconds</p>
<p><br role="presentation" /><strong>TYPICAL SYSTEM RESPONSE</strong><br role="presentation" />AVR response 10 ms<br role="presentation" />Filed current to 90% 80 ms<br role="presentation" />Machine Volts to 97% 300 ms</p>
<p><br role="presentation" /><strong>EXTERNAL VOLTAGE ADJUSTMENT</strong><br role="presentation" />+/-10% with 5 k ohm 1 watt trimmer (see note 4)</p>
<p><br role="presentation" /><strong>UNDER FREQUENCY PROTECTION</strong><br role="presentation" />Set point 95% Hz (see note 5)<br role="presentation" />Slope 100-300% down to 30 Hz<br role="presentation" />Max. Dwell 20% volts/S recovery</p>
<p><br role="presentation" /><strong>UNIT POWER DISSIPATION</strong><br role="presentation" />18 watts maximum</p>
<p><br role="presentation" /><strong>ANALOGUE INPUT</strong><br role="presentation" />Maximum input +/- 5 Vdc (see note 6)<br role="presentation" />Sensitivity 1v for 5% Generator Volts (adjustable)<br role="presentation" />Input resistance 1k ohm</p>
<p><br role="presentation" /><strong>QUADRATURE DROOP INPUT</strong><br role="presentation" />10 ohms burden<br role="presentation" />Max. sensitivity: 0.22 A for 5% droop 0PF<br role="presentation" />Max. input: 0.33 A</p>
<p><br role="presentation" /><strong>CURRENT LIMIT INPUT</strong><br role="presentation" />10 ohms burden<br role="presentation" />Sensitivity range: 0.5 – 1A</p>
<p><br role="presentation" /><strong>OVER VOLTAGE DETECTOR INPUT</strong><br role="presentation" />Set point: 300v. Time delay: 1 Sec (fixed)<br role="presentation" />CB trip coil volts: 10-30 vdc<br role="presentation" />CB trip coil resistance: 20-60 ohms</p>
<p><br role="presentation" /><strong>OVER EXCITATION PROTECTION</strong><br role="presentation" />Set point 75 V dc<br role="presentation" />Time delay 8-15 seconds (fixed)</p>
<h6 id="elementor-tab-title-2182" role="tab" data-tab="2" aria-controls="elementor-tab-content-2182"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/MX321.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R250</title>
		<link>https://tnkgenparts.com/product/r250/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=766</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li><span id="page17R_mcid118" class="markedContent"><span dir="ltr" role="presentation">The alternator with Shunt excitation is self-</span></span><span id="page17R_mcid119" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">excited with an R250 voltage regulator.</span></span><span id="page17R_mcid120" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">The regulator monitors the exciter excitation</span></span><span id="page17R_mcid121" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">current as a function of the alternator output</span></span><span id="page17R_mcid122" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">voltage. Very simple in design, the alternator</span></span><span id="page17R_mcid123" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">with</span> <span dir="ltr" role="presentation">shunt</span> <span dir="ltr" role="presentation">excitation</span> <span dir="ltr" role="presentation">has</span> <span dir="ltr" role="presentation">no</span> <span dir="ltr" role="presentation">sustaining</span></span><span id="page17R_mcid124" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">short-circuit capacity.</span></span></li>
 	<li>parallel running with other similarly equipped generators.</li>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" data-tab="1" role="tab" aria-controls="elementor-tab-content-2181">
																		<a href="">Data Download</a><br />
					</h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"> </td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/R250.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R450</title>
		<link>https://tnkgenparts.com/product/r450/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=767</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li><span id="page17R_mcid132" class="markedContent"><span dir="ltr" role="presentation">The R450 AVR is supplied in a casing</span></span><span id="page17R_mcid133" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">designed to be mounted on a panel with</span></span><span id="page17R_mcid134" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">dampers.</span></span><span id="page17R_mcid135" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Operating temperature: - 40°C to + 65°C</span></span><span id="page17R_mcid136" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Storage temperature: -- 55°C to + 85°C</span></span><span id="page17R_mcid137" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">- Shocks on the base: 9 g depending on the</span></span><span id="page17R_mcid138" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">3 axes.</span></span><span id="page17R_mcid139" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">-</span> <span dir="ltr" role="presentation">Vibrations:</span> <span dir="ltr" role="presentation">less</span> <span dir="ltr" role="presentation">than</span> <span dir="ltr" role="presentation">10</span> <span dir="ltr" role="presentation">Hz,</span> <span dir="ltr" role="presentation">2</span> <span dir="ltr" role="presentation">mm</span></span><span id="page17R_mcid140" class="markedContent"></span><span id="page17R_mcid141" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">half-peak amplitude.</span></span><span id="page17R_mcid142" class="markedContent"><br role="presentation" /><span dir="ltr" role="presentation">10 Hz to 100 Hz: 100mm/s, above 100 Hz</span></span><span id="page17R_mcid143" class="markedContent"><br role="presentation" /></span></li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/R250.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>C30AF</title>
		<link>https://tnkgenparts.com/product/c30af/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=759</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<div class="content">Universal Full Wave Self Excited
for brush and brushless alternator</div>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Specifications</a></h6>
<p><strong>Sensing &amp; Power Input</strong></p>
<p>Voltage                      160  260 Vac, 1 phase 2 wires</p>
<p>Frequency                50/60 Hz, selectable</p>
<p><strong>     Excitation Output</strong></p>
<p>Voltage                      Max. 180 Vdc</p>
<p>Current                      Continuous 20A</p>
<p>Intermittent             30A for 10 secs.</p>
<p>Resistance                Min. 3 ohms</p>
<p><strong>External Voltage Adjustment</strong></p>
<p>Max. +/- 10% @ 5K ohms 1 watt potentiometer</p>
<p><strong>Voltage Regulation</strong></p>
<p>Less than +/- 1% ( with 4% engine governing )</p>
<p><strong>Build Up Voltage</strong></p>
<p>5 Vac residual volts at power input terminal</p>
<p><strong>     Soft Start Ramp Time</strong></p>
<p>2 secs. +/- 10%</p>
<p><strong>Under Frequency Protection (Factory Presets)</strong></p>
<p>50 Hz system presets knee point at 45 Hz</p>
<p>60 Hz system presets knee point at 55 Hz</p>
<h6 id="elementor-tab-title-2182" role="tab" data-tab="2" aria-controls="elementor-tab-content-2182"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/C30AF-manual-TNK.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SX460</title>
		<link>https://tnkgenparts.com/product/sx460/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=760</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li>SX460 is a half-wave phase-controlled thyristor type Automatic Voltage Regulator (AVR) and forms part of the excitation system for a brush-less generator.</li>
 	<li>In addition to regulating the generator voltage, the AVR circuitry includes under-speed and sensing loss protection features. Excitation power is derived directly from the generator terminals.</li>
 	<li>Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the power circuitry of the AVR.</li>
 	<li>The AVR is linked with the main stator windings and the exciter field windings to provide closed loop control of the output voltage with load regulation of +/- 1.0%.</li>
 	<li>In addition to being powered from the main stator, the AVR also derives a sample voltage from the output windings for voltage control purposes. In response to this sample voltage, the AVR controls the power fed to the exciter field, and hence the main field, to maintain the machine output voltage within the specified limits, compensating for load, speed, temperature and power factor of the generator.</li>
 	<li>A frequency measuring circuit continually monitors the generator output and provides output under-speed protection of the excitation system, by reducing the output voltage proportionally with speed below a pre-settable threshold. A manual adjustment is provided for factory setting of the under frequency roll off point, (UFRO). This can easily be changed to 50 or 60 Hz in the field by pushon link selection.</li>
 	<li>Provision is made for the connection of a remote voltage trimmer, allowing the user fine control of the generator's output.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" data-tab="1" role="tab" aria-controls="elementor-tab-content-2181">
																		<a href="">Specifications</a><br />
					</h6>
<p><strong>INPUT</strong></p>
<ul>
<li>Voltage Jumper selectable 95-132V ac or 190-264V ac Frequency 50-60 Hz nominal Phase 1</li>
</ul>
<p><strong>OUTPUT </strong></p>
<ul>
<li>Voltage max 90V dc at 207V ac input Current continuous 4 A dc Intermittent 6 A for 10 secs Resistance 15 ohms minimum</li>
</ul>
<p><strong>REGULATION </strong></p>
<ul>
<li>+/- 1.0% (see note 1)</li>
</ul>
<p><strong>THERMAL DRIFT </strong></p>
<ul>
<li>0.05% per deg. C change in AVR ambient (note 2)</li>
</ul>
<p><strong>TYPICAL SYSTEM RESPONSE </strong></p>
<ul>
<li>AVR response 20 ms Filed current to 90% 80 ms Machine Volts to 97% 300 ms</li>
</ul>
<p><strong>EXTERNAL VOLTAGE ADJUSTMENT </strong></p>
<ul>
<li>+/-10% with 1 k ohm 1 watt trimmer (see note 3)</li>
</ul>
<p><strong>UNDER FREQUENCY PROTECTION </strong></p>
<ul>
<li>Set point 95% Hz (see note 4)</li>
<li>Slope 170% down to 30 Hz</li>
</ul>
<p><strong>UNIT POWER DISSIPATION</strong></p>
<ul>
<li>10 watts maximum</li>
</ul>
<p><strong> BUILD UP VOLTAGE </strong></p>
<ul>
<li>4 Volts @ AVR terminals</li>
</ul>
<h6 id="elementor-tab-title-2182" data-tab="2" role="tab" aria-controls="elementor-tab-content-2182">
																		<a href="">Data Download</a><br />
					</h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"> </td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/SX460-datasheet.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TCOM100</title>
		<link>https://tnkgenparts.com/product/tcom100/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=761</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<div class="content">Universal Full Wave Self Excited
for brush and brushless alternator</div>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" data-tab="1" role="tab" aria-controls="elementor-tab-content-2181">
																		<a href="">Specifications</a><br />
					</h6>
<p><strong>Power Input</strong></p>
<p>Voltage                      170 &#8211; 265 Vac, 1 phase 2 wires</p>
<p>Frequency                50/60 Hz, selectable</p>
<p><strong>Sensing Input</strong></p>
<p>Voltage                      220/380/440 Vac, selectable</p>
<p><strong>     Excitation Output</strong></p>
<p>Voltage                      Max. 180 Vdc</p>
<p>Current                      Continuous 30A</p>
<p>Intermittent             40A for 10 secs.</p>
<p>Resistance                Min. 3 ohms</p>
<p>     <strong>External Voltage Adjustment</strong></p>
<p>Max. +/- 10% @ 1K ohms 1 watt potentiometer</p>
<p>     <strong>Voltage Regulation</strong></p>
<p>Less than +/- 1% ( with 4% engine governing )</p>
<p>     <strong>Build Up Voltage</strong></p>
<p>5 Vac residual volts at power input terminal</p>
<p><strong>     Soft Start Ramp Time</strong></p>
<p>2 secs. +/- 10%</p>
<p>     <strong>Under Frequency Protection (Factory Presets)</strong></p>
<p>50 Hz system presets knee point at 45 Hz</p>
<p>60 Hz system presets knee point at 55 Hz</p>
<h6 id="elementor-tab-title-2182" data-tab="2" role="tab" aria-controls="elementor-tab-content-2182">
																		<a href="">Data Download</a><br />
					</h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"> </td>
<td colspan="1" rowspan="1">Download</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>