<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EA350 &#8211; TNK Genparts</title>
	<atom:link href="https://tnkgenparts.com/product-tag/ea350/feed/" rel="self" type="application/rss+xml" />
	<link>https://tnkgenparts.com</link>
	<description>Generator spare parts</description>
	<lastBuildDate>Wed, 21 Feb 2024 03:13:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.1</generator>

<image>
	<url>https://tnkgenparts.com/wp-content/uploads/2024/02/cropped-Site-logo-32x32.png</url>
	<title>EA350 &#8211; TNK Genparts</title>
	<link>https://tnkgenparts.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>EA350</title>
		<link>https://tnkgenparts.com/product/ea350/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:13:09 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=579</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator 73Vdc 3.5Amp</h2>
<div class="content">EA350 self excited brushless type genset voltage regulator is a compatible replacement for Marathon SE350 regulator and Basler AVC63-4D regulator.
<strong>SE350 and AVC 63-4D only fits 220 Vac generators, please use EA350-220V for direct replacement.</strong>
<img src="https://www.kutai.com.tw/images/icons/ce-logo-dark.png" />EN61204-3:2001 Certified</div>
<ul class="notes">
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" data-tab="1" role="tab" aria-controls="elementor-tab-content-2181">
																		<a href=""> Features</a><br />
					</h6>
<ul>
<li>Voltage regulation less than +/-1%</li>
<li>Optional 120/240 Vac sensing input switch</li>
<li>50/60 Hz selectable</li>
<li>Under frequency protection</li>
<li>Built-in high breaking capacity fuse</li>
<li>EMI Suppression</li>
</ul>
<h6 id="elementor-tab-title-2182" data-tab="2" role="tab" aria-controls="elementor-tab-content-2182">
																		<a href=""> Specifications</a><br />
					</h6>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Specifications</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Sensing and Power Input</td>
<td>
<ul>
<li>Voltage 85 to 135 Vac / 190 to 240 Vac</li>
<li>Frequency 50/60 Hz Jumper selectable</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Output</td>
<td>
<ul>
<li>Voltage Max. 36 Vdc @ power input 120 Vac / Max. 73 Vdc @ power input 240 Vac</li>
<li>Current Continuous 4A Intermittent 7A for 10 seconds (52/105 Vdc)</li>
<li>Resistance Min. 15 ohms Max. 100 ohms</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Voltage Regulation</td>
<td>
<ul>
<li>Less than +/-1% (with 4% engine governing)</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Build Up Voltage</td>
<td>
<ul>
<li>Residual voltage at AVR terminal greater than 5Vac</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">External Voltage Adjustment</td>
<td>
<ul>
<li>+/-5% @ 1K ohm 1 watt potentiometer</li>
<li>+/-10% @ 2K ohm 1 watt potentiometer</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">EMI Suppression</td>
<td>
<ul>
<li>Internal electromagnetic interference filtering</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Unit Power Dissipation</td>
<td>
<ul>
<li>Max. 8 watts</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Under Frequency Protection (Factory Presets)</td>
<td>
<ul>
<li>50 Hz system presets knee point at 45 to 51 Hz</li>
<li>60 Hz system presets knee point at 54 to 61 Hz</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>AVR Control Functions</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">VOLT</td>
<td>
<ul>
<li>Voltage adjustment</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">STAB</td>
<td>
<ul>
<li>Stability adjustment</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">U/F</td>
<td>
<ul>
<li>Setting under frequency protection knee point</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Environment</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Operating Temperature</td>
<td>
<ul>
<li>-40 to +60 °C</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Storage Temperature</td>
<td>
<ul>
<li>-65 to +85 °C</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Relative Humidity</td>
<td>
<ul>
<li>Max. 95%</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Vibration</td>
<td>
<ul>
<li>1.3 Gs @ 5 to 26 Hz</li>
<li>5.0 Gs @ 52 to 1000 Hz</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p><img decoding="async" src="https://www.kutai.com.tw/images/icons/ce-logo-large.png" /></p>
<table>
<thead>
<tr>
<th colspan="3" scope="col">
<h4>CE Test Standards</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">EN61204-3:2001</td>
<td>
<ul>
<li>CISPR 22 Class B</li>
<li>IEC61000-3-2:2005+A1:2800+A2:2009</li>
<li>IEC61000-3-3:2008</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">EN61204-3:2001</td>
<td>
<ul>
<li>IEC61000-4-2:2008
</li>
<li>IEC61000-4-4:2004+A1:2010</li>
<li>IEC61000-4-6:2008</li>
</ul>
</td>
<td>
<ul>
<li>IEC61000-4-3:2006+A1:2007+A2:2010</li>
<li>IEC61000-4-5:2005</li>
<li>IEC61000-4-11:2004</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Physical Specifications</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Dimension</td>
<td>
<ul>
<li>98.7 (L) x 67.0 (W) x 47.5 (H) mm</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Weight</td>
<td>
<ul>
<li>205 g +/-2%</li>
</ul>
</td>
</tr>
</tbody>
</table>