<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EA45A220HL &#8211; TNK Genparts</title>
	<atom:link href="https://tnkgenparts.com/product-tag/ea45a220hl/feed/" rel="self" type="application/rss+xml" />
	<link>https://tnkgenparts.com</link>
	<description>Generator spare parts</description>
	<lastBuildDate>Wed, 21 Feb 2024 03:13:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.1</generator>

<image>
	<url>https://tnkgenparts.com/wp-content/uploads/2024/02/cropped-Site-logo-32x32.png</url>
	<title>EA45A220HL &#8211; TNK Genparts</title>
	<link>https://tnkgenparts.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>EA45A220HL / EA45A220FL</title>
		<link>https://tnkgenparts.com/product/ea45a220hl-ea45a220fl/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:13:09 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=566</guid>

					<description><![CDATA[<h2 class="sub-title">Carbon Brush Gensets AVR 45Amp</h2>
<div class="content">EA45A220HL (Half Wave) and EA45A220FL (Full Wave) 45Amp universal self excited genset voltage regulator compatible replacement for carbon brush type generators. There are also optional low frequency protection available.
Parallel version is available for option.</div>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" data-tab="1" role="tab" aria-controls="elementor-tab-content-2181">
																		<a href=""> Features</a><br />
					</h6>
<ul>
<li>Voltage regulation less than +/-1%</li>
<li>50/60 Hz selectable</li>
<li>Full wave and half wave version available</li>
<li>Adjustable voltage, stability and field limit</li>
<li>Built-in high breaking capacity fuse</li>
<li>Forced-Air Cooling by internal fan</li>
<li>Under frequency protection</li>
</ul>
<h6 id="elementor-tab-title-2182" data-tab="2" role="tab" aria-controls="elementor-tab-content-2182">
																		<a href=""> Specifications</a><br />
					</h6>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Specifications</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Sensing Input</td>
<td>
<ul>
<li>Voltage 170 to 265 Vac 1 phase 2 wire</li>
<li>Frequency 50/60 Hz selectable</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Output (at 220 Vac input)</td>
<td>
<ul>
<li>Voltage</li>
<li>EA45A220HL Max. 90 Vdc</li>
<li>EA45A220FL Max. 180 Vdc</li>
<li>Current Continuous 45A, Intermittent 60A for 10 seconds</li>
<li>Resistance</li>
<li>EA45A220HL Min. 1.4 ohms</li>
<li>EA45A220FL Min. 2.7 ohms</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Voltage Regulation</td>
<td>
<ul>
<li>Less than +/-1% (with 4% engine governing)</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Build Up Voltage <sup>*1</sup></td>
<td>
<ul>
<li>Residual volts at AVR terminal greater than 5 Vac @ 25 Hz</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">External Voltage Adjustment</td>
<td>
<ul>
<li>+/-6%</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Under Frequency Protection<br />(Factory Presets)</td>
<td>
<ul>
<li>50 Hz system presets knee point at 45 Hz</li>
<li>60 Hz system presets knee point at 55 Hz</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Environment</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Operating Temperature</td>
<td>
<ul>
<li>-40 to +60 °C</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Storage Temperature</td>
<td>
<ul>
<li>-40 to +85 °C</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Relative Humidity</td>
<td>
<ul>
<li>Max. 95%</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Vibration</td>
<td>
<ul>
<li>3.0 Gs @ 100 to 2K Hz</li>
</ul>
</td>
</tr>
</tbody>
</table>
<table>
<thead>
<tr>
<th colspan="2" scope="col">
<h4>Physical Specifications</h4>
</th>
</tr>
</thead>
<tbody>
<tr>
<td scope="row">Dimensions</td>
<td>
<ul>
<li>330.0 (L) x 189.0 (W) x 180.0 (H) mm</li>
</ul>
</td>
</tr>
<tr>
<td scope="row">Weight</td>
<td>
<ul>
<li>EA45A220HL 4.5 Kg +/-2%</li>
<li>EA45A220FL 5.2 Kg +/-2%</li>
</ul>
</td>
</tr>
</tbody>
</table>
<aside>
<ol>
<li>If residual voltage is below 5Vac, user is suggested to install <a href="https://www.kutai.com.tw/products/generator-automatic-voltage-regulator/eb500">EB500</a> (auto flash module) to safely flash the field and build up residual voltage, or carefully execute manual field flash (see the below picture) for more information please click on the below links for more information.</li>