<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MX321 &#8211; TNK Genparts</title>
	<atom:link href="https://tnkgenparts.com/product-tag/mx321/feed/" rel="self" type="application/rss+xml" />
	<link>https://tnkgenparts.com</link>
	<description>Generator spare parts</description>
	<lastBuildDate>Wed, 21 Feb 2024 03:15:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.1</generator>

<image>
	<url>https://tnkgenparts.com/wp-content/uploads/2024/02/cropped-Site-logo-32x32.png</url>
	<title>MX321 &#8211; TNK Genparts</title>
	<link>https://tnkgenparts.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MX321</title>
		<link>https://tnkgenparts.com/product/mx321/</link>
		
		<dc:creator><![CDATA[Thanakorn Taechapornrapat]]></dc:creator>
		<pubDate>Wed, 21 Feb 2024 03:14:15 +0000</pubDate>
				<guid isPermaLink="false">https://tnkgenparts.com/?post_type=product&#038;p=765</guid>

					<description><![CDATA[<h2 class="sub-title">Automatic Voltage Regulator</h2>
<ul>
 	<li>MX321 is a three phase sensed Automatic Voltage
Regulator and forms part of the excitation system for a
brush-less generator. Excitation power is derived from a
three-phase permanent magnet generator (PMG), to
isolate the AVR control circuits from the effects of non-
linear loads and to reduce radio frequency interference on
the generator terminals. Sustained generator short circuit
current is another feature of the PMG system.</li>
 	<li>The AVR senses the voltage in the main generator winding
and controls the excitation to maintain the generator output
voltage within the specified limits, compensating for load,
speed, temperature and power factor of the generator.
Three phase RMS sensing is employed for superior
voltage regulation.</li>
 	<li>Adjustable Soft start circuitry is included to provide a
smooth controlled build up of generator output voltage.</li>
 	<li>A frequency measuring circuit continually monitors the
shaft speed of the generator and provides under-speed
protection of the excitation system by reducing the
generator output voltage proportionally with speed below a
pre-settable threshold. A further enhancement of this
feature is an adjustable volts per Hertz slope and voltage
recovery time, to improve the response of turbo charged
engines.</li>
 	<li>Current limiting may be included to allow control over the
amount of sustained short circuit current.</li>
 	<li>Maximum excitation is limited to a safe period by internal
shutdown of the AVR output device. This condition remains
latched until the generator has stopped.</li>
 	<li>The AVR includes an over-voltage protection feature with
internal shutdown of the AVR output device, plus the ability
to trip an optional excitation circuit breaker if required.</li>
 	<li>Provision is made for the connection of a remote voltage
trimmer, allowing the user fine control of the generator's
output.</li>
 	<li>An analogue input is provided allowing connection to a
Newage Power Factor controller or other external device
with compatible output.</li>
 	<li>The AVR has the facility for droop CT connection, to allow
parallel running with other similarly equipped generators.</li>
</ul>
&#160;
<ul>
 	<li>All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h6 id="elementor-tab-title-2181" role="tab" data-tab="1" aria-controls="elementor-tab-content-2181"><a>Specifications</a></h6>
<p><strong>SENSING INPUT</strong><br role="presentation" />Voltage 190-264V ac max, 2 or 3 phase<br role="presentation" />Frequency 50-60 Hz nominal</p>
<p><br role="presentation" /><strong>POWER INPUT (PMG)</strong><br role="presentation" />Voltage 170-220V ac max, 3 phase, 3 wire<br role="presentation" />Current 3A/phase<br role="presentation" />Frequency 100-120 Hz nominal</p>
<p><br role="presentation" /><strong>OUTPUT</strong><br role="presentation" />Voltage max 120V dc<br role="presentation" />Current continuous 3.7 A (see note 1)<br role="presentation" />Intermittent 6A for 10 secs.<br role="presentation" />Resistance 15 ohms minimum</p>
<p><br role="presentation" /><strong>REGULATION</strong><br role="presentation" />+/- 0.5% RMS with 4% engine governing (see note 2)</p>
<p><br role="presentation" /><strong>THERMAL DRIFT</strong><br role="presentation" />0.02% per deg. C change in AVR ambient (note 3)</p>
<p><br role="presentation" /><strong>SOFT START RAMP TIME</strong><br role="presentation" />0.4 – 4 seconds</p>
<p><br role="presentation" /><strong>TYPICAL SYSTEM RESPONSE</strong><br role="presentation" />AVR response 10 ms<br role="presentation" />Filed current to 90% 80 ms<br role="presentation" />Machine Volts to 97% 300 ms</p>
<p><br role="presentation" /><strong>EXTERNAL VOLTAGE ADJUSTMENT</strong><br role="presentation" />+/-10% with 5 k ohm 1 watt trimmer (see note 4)</p>
<p><br role="presentation" /><strong>UNDER FREQUENCY PROTECTION</strong><br role="presentation" />Set point 95% Hz (see note 5)<br role="presentation" />Slope 100-300% down to 30 Hz<br role="presentation" />Max. Dwell 20% volts/S recovery</p>
<p><br role="presentation" /><strong>UNIT POWER DISSIPATION</strong><br role="presentation" />18 watts maximum</p>
<p><br role="presentation" /><strong>ANALOGUE INPUT</strong><br role="presentation" />Maximum input +/- 5 Vdc (see note 6)<br role="presentation" />Sensitivity 1v for 5% Generator Volts (adjustable)<br role="presentation" />Input resistance 1k ohm</p>
<p><br role="presentation" /><strong>QUADRATURE DROOP INPUT</strong><br role="presentation" />10 ohms burden<br role="presentation" />Max. sensitivity: 0.22 A for 5% droop 0PF<br role="presentation" />Max. input: 0.33 A</p>
<p><br role="presentation" /><strong>CURRENT LIMIT INPUT</strong><br role="presentation" />10 ohms burden<br role="presentation" />Sensitivity range: 0.5 – 1A</p>
<p><br role="presentation" /><strong>OVER VOLTAGE DETECTOR INPUT</strong><br role="presentation" />Set point: 300v. Time delay: 1 Sec (fixed)<br role="presentation" />CB trip coil volts: 10-30 vdc<br role="presentation" />CB trip coil resistance: 20-60 ohms</p>
<p><br role="presentation" /><strong>OVER EXCITATION PROTECTION</strong><br role="presentation" />Set point 75 V dc<br role="presentation" />Time delay 8-15 seconds (fixed)</p>
<h6 id="elementor-tab-title-2182" role="tab" data-tab="2" aria-controls="elementor-tab-content-2182"><a>Data Download</a></h6>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="1" rowspan="1">English Manual</td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"><a href="https://thaigenset.com/wp-content/uploads/2023/05/MX321.pdf">Download</a></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		